Model NO.: QDX, QX series submersible pump
-
Max.Capacity: >400 L/min
-
Material: Aluminum Housing
-
Assembly: impeller
-
Start Up: Electric Pump
-
Application: Submersible Pump, Clarified Water Pump
-
Media: Clean Water
-
Theory: Centrifugal Pump
-
Transport Package: 1PCS/Carton
-
Origin: ZheJiang, China
-
Max.Head: 10-30m
-
Driving Type: Motor
-
Structure: Single-stage Pump
-
Power: Electric
-
Type: Submersible Pump
-
Industry: Industry and Agriculture
-
Performance: Submersible Pump
-
Trademark: kaili
-
Specification: 0.5-3HP
-
HS Code: 8413709190
  Pump Introduction Â
 QDX, QX series submersible pump consists of pump, mechanical seal and motor. Pump is at the bottom part of pump, which is adopted centrifugal impeller. Motor which is single-phase or three-phase is at the upper part of pump. Seal is used where pump and motor combine, which is a kind of double-end mechanical seal, O rings are applied to all static joints. Float switch can be equipped to control pump's starting and stopping automatically according to the water level.Main Application  This series pump is small and light, which is widely used in countryside for elevating water from well, irrigation, sprinkling and domestic water supply, and also used in draining off water for fishpond and building site.Work conditionsThe pump can work properly and continuously under following operational conditions:
1. Medium is not corrosive,Sand contents should be max. 0.01% by volume and Â
   granular size should be max. 0.2mm.
2. Medium temperature shouldn't be over 40°C and PH should be 6.5-8.5.
3. The pumps should be operated within rated head.
4. The pumps should be fully submerged into water with depth of less than 3m      mad max. the pump should be min. 0.5m over the water bottom and not be insert into sludge.
5.Power frequency should be 50HZ,single phase voltage 220V,three phase voltage 380V,and voltage fluctuation should be 0.9-1.1 times than the rated.Workplace Show
Features of Kaili Submersible Pump1. 100% copper wire
2. Chrome-plated pump rotor (more resistant to wear and corrode)
3. Thermal protector
4. High-end bearing and mechanical sealMaterial
Structure of pump
|
Material |
Can be selected |
Pump body |
Aluminum |
Cast-Iron / Stainless steel |
Impeller |
Aluminum |
Stainless steel |
Pump shaft |
45 # Steel |
Stainless steel |
Cable |
/ |
Arbitrary length |
Â
Specification
Appellation |
Model |
Flow |
Head (m) |
Power (kW) |
HP |
Pipe size |
Voltage (v) |
Velocity (r/min) |
m³/h |
l/min |
(mm) |
(inch) |
QDX Single-phase Submersible Pump |
QDX 1.5-16-0.37 |
1.5 |
25 |
16 |
0.37 |
0.5 |
25 |
1 |
220 |
2860 |
QDX 3-20-0.55 |
3 |
50 |
20 |
0.55 |
0.75 |
25 |
1 |
QDX 10-10-0.55 |
10 |
166.7 |
10 |
0.55 |
0.75 |
40 |
1.5 |
QDX 15-7-0.55 |
15 |
250 |
7 |
0.55 |
0.75 |
50 |
2 |
QDX 1.5-32-0.75 |
1.5 |
25 |
32 |
0.75 |
1 |
25 |
1 |
QDX 7-18-0.75 |
7 |
117 |
18 |
0.75 |
1 |
40 |
1.5 |
QDX 10-16-0.75 |
10 |
166.7 |
16 |
0.75 |
1 |
50 |
2 |
QDX 15-10-0.75 |
15 |
250 |
10 |
0.75 |
1 |
65 |
2.5 |
QDX 10-16-0.8 |
10 |
166.7 |
16 |
0.8 |
1.1 |
25/40/50 |
1/1.5/2 |
QDX 1.5-38-1.1 |
1.5 |
25 |
38 |
1.1 |
1.5 |
25 |
1 |
QDX 10-20-1.1 |
10 |
166.7 |
20 |
1.1 |
1.5 |
50 |
2 |
QDX 15-15-1.1 |
15 |
250 |
15 |
1.1 |
1.5 |
65 |
2.5 |
QDX 30-9-1.1 |
30 |
500 |
9 |
1.1 |
1.5 |
80 |
3 |
QDX 15-18-1.5 |
15 |
250 |
18 |
1.5 |
2 |
65 |
2.5 |
QDX 40-9-1.5 |
40 |
667 |
9 |
1.5 |
2 |
80 |
3 |
QDX 65-7-2.2 |
65 |
1083 |
7 |
2.2 |
3 |
100 |
4 |
QX Three-phase Submersible Pump |
QX 3-20-0.55 |
3 |
50 |
20 |
0.55 |
0.75 |
25 |
1 |
380 |
3000 |
QX 10-10-0.55 |
10 |
166.7 |
10 |
0.55 |
0.75 |
40 |
1.5 |
QX 15-7-0.55 |
15 |
250 |
7 |
0.55 |
0.75 |
50 |
2 |
QX 1.5-32-0.75 |
1.5 |
25 |
32 |
0.75 |
1 |
25 |
1 |
QX 7-18-0.75 |
7 |
117 |
18 |
0.75 |
1 |
40 |
1.5 |
QX 10-16-0.75 |
10 |
166.7 |
16 |
0.75 |
1 |
50 |
2 |
QX 15-10-0.75 |
15 |
250 |
10 |
0.75 |
1 |
65 |
2.5 |
QX 10-20-1.1 |
10 |
166.7 |
20 |
1.1 |
1.5 |
50 |
2 |
QX 15-15-1.1 |
15 |
250 |
15 |
1.1 |
1.5 |
65 |
2.5 |
QX 30-9-1.1 |
30 |
500 |
9 |
1.1 |
1.5 |
80 |
3 |
QX 15-18-1.5 |
15 |
250 |
18 |
1.5 |
2 |
65 |
2.5 |
QX 40-9-1.5 |
40 |
667 |
9 |
1.5 |
2 |
80 |
3 |
QX 65-7-2.2 |
65 |
1083 |
7 |
2.2 |
3 |
100 |
4 |
Sewage Submersible Pump |
QDX 6-12-0.4 |
6 |
100 |
12 |
0.4 |
0.55 |
25/32 |
1/1.5 |
220 |
2860 |
QDX 10-15-0.75 |
10 |
166.7 |
15 |
0.75 |
1 |
25/40 |
1.5/2 |
QDX 10-18-1.1 |
10 |
166.7 |
18 |
1.1 |
1.5 |
25/40 |
1.5/2 |
QX 10-18-1.1 |
10 |
166.7 |
18 |
1.1 |
1.5 |
25/40 |
1.5/2 |
380 |
3000 |
QDX Cast-iron body Submersible Pump |
QDX 3-14-0.37T |
3 |
50 |
14 |
0.37 |
0.5 |
25 |
1 |
220 |
2860 |
QDX 3-18-0.55T |
3 |
50 |
18 |
0.55 |
0.75 |
25 |
1 |
QDX 3-24-0.75T |
3 |
50 |
24 |
0.75 |
1 |
25 |
1 |
QDX 3-30-1.1T |
3 |
50 |
30 |
1.1 |
1.5 |
25 |
1 |
QDX 6-32/2-1.5T |
6 |
100 |
32 |
1.5 |
2 |
40 |
1.5 |
According to regulations, live birds reception should be at the wind down area of the processing plant. Including parking area, slaughtering-waiting area, unloading ,live birds hanging, stunning and bleeding area, crates cleaning, crate pelleting,vehicle disinfection area,waste store ,reception and urgent killing area and so on. The slaughterhouse is appropriate to single layer, net height is not less than 4.2 meter, the polar space not less than 6 meter, hanging area is the main workshop bleeding room design to be darkroom which separate with our working area.Close to one side to receiving area is to be working area, including clearing room, official quarantine room, if have halal products, should with one rest room for Iman.
1.Live poultry vehicles should have special road. There is a disinfection pool which same wide as door at the entrance for live poultry enter..The pool size is about 3 meters long and 100 to 150mm deep.
2. UnloadingThe platform built which height is same as vehicles which save much labor. Two workers unloading crates from vehicle,each time unload 8 to 9 layer of crate, each hour unloading 12000birds. Normally unloading platform should be keep some crates. According to WSPA regulations, when live birds reach slaughterhouse should be killed within 1hour,max. Not more than 2 hours, for one slaughterhouse which to slaughter 12000birds/H, the parking place should be suitable for 5 trucks, unloading area is suitable for 2 trucks, crates pelleting area is suitable for 3 trucks, and with spare crates storage room to keep spare crates.
3. Live birding hangingThere should be a darkroom after birds hanging and stunning, the orbit of overhead conveyor line should be kept level,straight ,try to reduce the turns and movements; The overhead conveyor line with synchronous control system and emergency stop system to ensure the reliable running of the processing line. The appropriate shackles are used according to different type of poultry and raising period; Try to keep poultry appease to prevent wings injury from struggling to ensure meat quality.
Bird Reception Machine
Live Bird Receiving Unit, Chicken Hanging Unit, Live Bird Reception, Chicken Reception
Connect Group For Poultry Project , http://www.connectpoultry.com