Metal Body Square Water Cooling Tower This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results. Metal Body Square Water Cooling Tower,Tower Water Cooler,Water Cooled Cooling Tower,Tower Cooling System Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.com
In order to solve the problem of paper-making waste liquid pollution, Tianyi Paper, through continuous research and investigation, used a part of the products that could not be used in paper-making to produce organic compound fertilizers, etc., to dry, crush, and incorporate activated sludge into fertilizers. In the middle, the raw materials were "dried." Since the company's production of organic compound fertilizer from the ammonium sulfite method wheat straw pulping black liquor has been completed, the papermaking waste liquid has been effectively used, which not only solves the environmental protection problem, but also allows the company to have a foundation for dealing with the financial crisis.
The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.
The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.
The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.
Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.
When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.
The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).
The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.
When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.
Anhui Tianyi Paper Co., Ltd., located in Guoyang County, changed the traditional production mode according to the concept of circular economy, turning the pollutants generated by papermaking into fertilizers, which not only solved the environmental protection problem, but also allowed the company to meet the financial crisis. .