[China Instrument Network Instrumentation Conference] Recently, the Jiangsu Province Flowmeter Professional Technical Committee held the Jiangsu Province Flowmeter Technical Specification Publicizing and Technical Exchange Conference in Yangzhou. Ma Yuming, chairman of the Provincial Flow Metering Professional Technical Committee, attended the meeting and delivered a speech. Zhao Wei, secretary general of the Provincial Flow Measurement Professional Technical Committee, presided over the meeting. More than 50 people from provincial technical institutions and related companies attended the meeting.

meeting venue
The main drafters of the national metrological technical specifications invited at the meeting made detailed explanations for the participants. Mr. Duan Huiming of China Institute of Metrology and Mr. Zhao Jianliang, Director of Zhejiang Institute of Metrology, respectively explained the newly promulgated JJG1132-2017 "Verification of Thermal Gas Mass Flowmeter Verification Rules" and JJG1113-2015 "Verification of Water Meter Verification Devices" and The latest type evaluation program for cold water meters explains in detail the key points and hot issues of the new and old regulations. Provincial Bureau of Metrology, Wang Ke Chief Engineer, Pan Le Director, and Dr. Yu Jun Lun were responsible for the drafting of the JJF1591-2016 "Coriolis mass flow meter type evaluation program", JJF1590-2016 "differential pressure flow meter type. The Outline of the Evaluation and JJF1591-2016 "Fluid Flowmeter Type Evaluation Outline" were specifically introduced, focusing on the background, process and principles of the introduction of the new specification.
At the meeting, participants also exchanged ideas on issues that occurred during their daily work.
Through this promotion and exchange, participants expressed that they have a more comprehensive and profound understanding of the procedural regulations, improved their practical work capacity, and laid the foundation for the smooth implementation of the new regulations. The provincial flow metering professional and technical committee will further develop its functions and continue to carry out various types of technical exchange training to promote the continuous improvement of the flow measurement technology level in the province and to serve the socio-economic development.
(Original title: In 2017, the Jiangsu Province Flow Measurement Technical Specification Promotion and Technical Conference was held in Yangzhou)

Polymer Concrete Cells For ER/EW Processing Of Nonferrous

  1. Vinyl ester resin monolithic casting electrolytic cells
Electrolytic cells are designed, built and installed to satisfy the most stringent requirements requested by tankhouse operators worldwide. In most cases their main request is to guarantee full operating availability throughout the plant's lifespan, maximizing production of high-purity metal (copper, zinc, nickel, cobalt, lead or other nonferrous metals) with absolute safety for people and the environment. Additionally, cells must accommodate changes for continuous improvement of the electrolytic process, integrating efficiently with upgrades of complementary equipment such as anodes, cathodes, cap, boards, overhead crane electrolyte agitation systems, acid mist control devices, thermal insulation among many others.
2. Structure
Electrolytic cells are cast monolithically based on a patented, three-layer composite material system:
The Internal layer is a monolithic tank made with multiple layers of fiber-reinforced vinyl ester resin (FRP) complying with chemical barrier international norms that assure long-term impermeability and corrosion resistance.
The Intermediate layer is the structural core made with polymer Concrete, with a patented formulation to achieve a low coefficient of thermal expansion, providing long-term structural integrity with low thermally-induced stresses
The External layer is a standard seal layer of FRP that further protects the structural core from electrolyte splashes and spills. Optionally,this external seal may be specified with multi-layered oriented fiber reinforcements to guarantee trouble-free operation in unusually extreme operating environments.
Benefits of electrolytic cells

Long-term impermeability, free of corrosion, 20+ years warranty
Our monolithic internal tank manufactured with multiple layers of fiber-reinforced premium vinyl ester resin. It has continuous service without leakage, free of corrosion and structural flaws which operating under normal conditions as specified for each project.
Swift, accurate and less costly installation
Electrolytic cells include features that allow reduction of 25% or more in time needed for cell erection, alignment and leveling compared to time required with conventional polymer concrete cells. Dimension tolerances for electrolytic cells are consistently tight, simplifying installation in the most demanding applications,including plants with automated crane systems.
Minimum cleaning time and water consumption
The rounded internal shape,optional sloped cell floors,and smooth,flat finish of the internal tank,facilitate water sweeping and drainage of heavy sludge,with reduced water usage and accelerating return to service after each cleaning.
Minimum maintenance cost
The robust, virtually impervious internal tank that is chemically bound to the polymer concrete structural core during molding is tolerant to operating abuse its smooth,non-stick surfaces minimize adhesion of contaminants.
Maximum operational safety

The structural core of electrolytic cells is bolstered with sturdy external seismic reinforcement blocks confining its floor supports, and includes a robust, internal bidirectional, pultruded FRP bar mesh reinforcement which positively maintains integrity should the cell fail due to catastrophic events. Electrolytic cell installation protocols call for lateral wall collaboration between cells,thus reducing stress levels of cell around 40% under normal operating conditions.

Electrolytic Cell 122Electrolytic Cell 127Electrolytic Cell 125Electrolytic Cell 91Electrolytic Cell 90Electrolytic Cell 88Electrolytic Cell 96

Polymer Concrete Electrolytic Cell,Electrolytic Cell Nickle,Electrolytic Cell Nickle Refining Tanks,Electrolytic Cells of Electroplating Equipment

Hebei aoliande Chemical Equipment Co., Ltd , https://www.frpgrppipe.com

Posted on