Structure: Floating
Type: Yokohama-Type, Net-Type, Sling-Type
Service Life: 10-20years
Certification: BV, ISO9001, CCS, ISO17357, ABS, Dnv, Lr
Capability: Water Rubber Hose
Load Capacity: >8000teu
Usage: Trade, Ship Launching, Protection, Ship Docking
Trademark: Star-Marine
HS Code: 40169400

Super Arch Rubber Fender

Super arch rubber fender, also called V type super arch rubber fender, can provide reliable service for protecting vessels and docks from damages even under the most severe conditions. By using bolts, it can be mounted to the docks horizontally or vertically to absorb impact energy and dissipate stress evenly with improved performance comparing with cylindrical fenders.
Features:
    1. Larger design compress deformation;
    2. higher energy absorption;
    3. lower reaction force;
    4. Reasonable structure and long usage life;
    5. Convenient and deep-set installation.

PRODUCT INTRODUCTION
Specifications(mm):
 
<

Closed Cooling Tower

Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.

First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.

Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.

Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.com

Posted on
Type Dimension (mm)
L L1 H h B B3 B2 B1 f e C b a Q hole
150 1000 1075 150 22.5 98 96 300 240 55 25 110 95 50 855 2
  1500 1575 150 22.5 98 96 300 240 55 25 112.5 95 50 675 3
  2000 2075 150 22.5 98 96 300 240 55 25 215 95 50 620 4
  2500 2575 150 22.5 98 96 300 240 550 25 220 95 50 785 4
  3000 3075 150 22.5 98 96 300 240 55 25 215 95 50 715 5
  3500 3575 150 22.5 98 96 300 240 55 25 220 95 50 671 6
200 1000 1100 200 30 145 128 400 320 75 29 120 105 58 860 1
  1500 1600 200 30 145 128 400 320 75 29 120 105 58 680 2
  2000 2100 200 30 145 128 400 320 75 29 120 105 58 620 3
  2500 2600 200 30 145 128 400 320 75 29 122.5 105 58 785 3
  3000 3100 200 30 145 128 400 320 75 29 120 105 58 715 4
  3500 3600 200 30 145 128 400 320 75 29 120 105 58 672 5
250 1000 1125 250 33 164 160 500 410 90 32 130 125 64 865 1
  1500 1625 250 33 164 160 500 410 90 32 132.5 125 64 680 2
  2000 2125 250