Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.
First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.
Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.
Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.
To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.
Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.comSuper Arch Rubber Fender
Super arch rubber fender, also called V type super arch rubber fender, can provide reliable service for protecting vessels and docks from damages even under the most severe conditions. By using bolts, it can be mounted to the docks horizontally or vertically to absorb impact energy and dissipate stress evenly with improved performance comparing with cylindrical fenders.
Features:
PRODUCT INTRODUCTION
Specifications(mm):
Â
Type
Dimension (mm)
L
L1
H
h
B
B3
B2
B1
f
e
C
b
a
Q
hole
150
1000
1075
150
22.5
98
96
300
240
55
25
110
95
50
855
2
Â
1500
1575
150
22.5
98
96
300
240
55
25
112.5
95
50
675
3
Â
2000
2075
150
22.5
98
96
300
240
55
25
215
95
50
620
4
Â
2500
2575
150
22.5
98
96
300
240
550
25
220
95
50
785
4
Â
3000
3075
150
22.5
98
96
300
240
55
25
215
95
50
715
5
Â
3500
3575
150
22.5
98
96
300
240
55
25
220
95
50
671
6
200
1000
1100
200
30
145
128
400
320
75
29
120
105
58
860
1
Â
1500
1600
200
30
145
128
400
320
75
29
120
105
58
680
2
Â
2000
2100
200
30
145
128
400
320
75
29
120
105
58
620
3
Â
2500
2600
200
30
145
128
400
320
75
29
122.5
105
58
785
3
Â
3000
3100
200
30
145
128
400
320
75
29
120
105
58
715
4
Â
3500
3600
200
30
145
128
400
320
75
29
120
105
58
672
5
250
1000
1125
250
33
164
160
500
410
90
32
130
125
64
865
1
Â
1500
1625
250
33
164
160
500
410
90
32
132.5
125
64
680
2
Â
2000
2125
250
<
Structure: Floating
Type: Yokohama-Type, Net-Type, Sling-Type
Service Life: 10-20years
Certification: BV, ISO9001, CCS, ISO17357, ABS, Dnv, Lr
Capability: Water Rubber Hose
Load Capacity: >8000teu
Usage: Trade, Ship Launching, Protection, Ship Docking
Trademark: Star-Marine
HS Code: 40169400